BTS-5V3AS1 is a precision eight-channel high-precision battery test system. This system is the best tool for researching new generation energy storage materials and rechargeable batteries. Designed in accordance with international standards, each channel system has an independent constant current source and constant voltage. Constant current source and constant voltage source can be programmed and controlled according to the scheme. In addition, each channel has an independent signal source to meet the dynamic requirements of internal resistance measurement.
Equipment introduction
BTS-5V3AS1 is a precision eight-channel high-precision battery test system. This system is the best tool for researching new generation energy storage materials and rechargeable batteries. Designed in accordance with international standards, each channel system has an independent constant current source and constant voltage. Constant current source and constant voltage source can be programmed and controlled according to the scheme. In addition, each channel has an independent signal source to meet the dynamic requirements of internal resistance measurement.
Each module provides eight independent programmable channels: built-in power supply and complete control circuit, each module can work independently. Each channel can be set with different working modes; precise programming features: the system software can set ± working steps and working parameters, and the flexibility of the working mode at each step. Working modes include constant current discharge, constant current charge, constant voltage charge, and rest. Each working mode can set voltage, current, time, power, negative voltage gradient, and other restrictions. When the current restrictions are met, the system will automatically continue to the next working mode. The set program can be saved and opened according to the schedule; complete controllability: the system software has GOTO, restart and recovery functions, allowing users to change working parameters at any time. Windows-based software interface, stable performance and easy to operate. The software operation of the system is simple. Real-time monitoring of the computer interface comprehensive graph/data window can more directly and effectively observe the test process. During the test, the software will provide timely instructions and warnings, and provide intelligent help in English and Chinese.
Performance indicators and basic configuration | ||||||
Input power | AC 220V ±10% / 50Hz and AC 110V ±10% / 50Hz adjustable | |||||
Input active power | 231W | |||||
Resolution | AD:16bit;DA:12bit | |||||
Input resistance | ≥1MΩ | |||||
Voltage | Constant voltage range control | 25mV~5V | ||||
Minimum discharge voltage | Both ends of the upper and lower clamps can be discharged to 1.0V, and the 2m line can be up to 1.5V | |||||
Precision | ± 0.1% of FS | |||||
Stability | ± 0.1% of FS | |||||
Current | Output range per channel | 15mA~3000mA | ||||
Precision | ± 0.1% of FS | |||||
Constant voltage cut-off current | 6mA | |||||
Stability | ± 0.1% of FS | |||||
Power | Single channel output power | 15W | ||||
Stability | ± 0.2% of FS | |||||
Time | Current response time | Maximum current rise time 20ms | ||||
Step time range | ≤(365*24)hour/step | |||||
Data record | Data recording conditions | Minimum sampling time: 1s | ||||
Minimum sampling voltage: 10mV | ||||||
Minimum sampling current: 6mA | ||||||
Recording frequency | 1Hz | |||||
Recharge | Charging mode | Constant current charging, constant voltage charging, constant current and constant voltage charging | ||||
Cut-off condition | Voltage, current, relative time, capacity, -△V | |||||
Discharge | Discharge mode | Constant current discharge, constant power discharge, constant resistance discharge | ||||
Cut-off condition | Voltage, current, relative time, capacity, -△V | |||||
Cycle | Cycle test range | 1~65535 times | ||||
Number of steps in a single cycle | 63 | |||||
Loop nesting | With nested loop function, maximum support 3 levels of nesting | |||||
Protection | Safety protection | l Power-down data protection | ||||
l Safety protection conditions can be set, setting parameters include: voltage upper limit, voltage lower limit, current upper limit, current lower limit, delay time | ||||||
Channel characteristics | Constant current source and constant voltage source adopt double closed loop structure | |||||
Channel control mode | Independent control | |||||
Voltage and current detection sampling | Four-wire connection | |||||
Noise | <85dB | |||||
Host computer communication method | RS232 (Note: PC computer must be equipped with serial port card) | |||||
Data output method | EXCEL2003、2010、TXT | |||||
Server disk configuration | 500GB | |||||
Server operating system | Windows 7 | |||||
Communication Interface | Serial port | |||||
Number of channels per unit | 8 | |||||
Equipment working environment requirements | ||||||
Index item | Index parameter | |||||
range of working temperature | 0℃~40℃ | |||||
Storage temperature range | -10℃~50℃ | |||||
Relative humidity range of working environment | ≤70% RH (no condensation) | |||||
Storage environment relative humidity range | ≤80% RH (no condensation) | |||||
Fixture specifications and dimensions | ||||||
Index item | Index parameter | |||||
Fixture type | Upper and lower clamps | |||||
Chassis size of each unit (W*D*H) | 3U1F, 480*400*130 (mm) | |||||
Total equipment size | 245L×197W×60H (mm) | |||||
Weight | 12KG | |||||
Fixture picture | ![]() | ![]() | ![]() | ![]() | ||
Upper and lower clamps | Alligator fixture | Polymer clamp | Wire nose | |||
The picture is for reference only, subject to the actual product |
Contact: Kaiying
Phone: 18938644707
Tel: 18938644707
Email: Kaiying@macex.com.cn
Add: Room 404, building 3, No.5, xingye 3rd road,fenghuang community,fuyong street,bao an district,shenzhen city,guangdong,China